Arietta Dekor Glass 30 Instruction Manual Page 10

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 9
10
Installation height: 30" gas cooktop/range or 24" to 30" electric cooktop/range.
The hood may be installed onto a wall and vented to the outdoors, or it can be installed for recirculating operation
(recirculating accessories not supplied with the hood).
This hood can be installed over any electric and gas cooktop/range. It can not be installed over any professional
cooktop / range.
Installing preparation
Advance planning
Determine the exact location of the vent hood.
Plan the route for venting exhaust to the outdoors.
Use the shortest and straightest duct route possible. For satisfactory performance duct run should not
exceed 100’ equivalent length for any duct configurations.
Refer to Duct Fittingschart to compute the maximum permissible length for duct runs to the outdoors.
Install a wall cap with damper or roof cap at the exterior opening. Order the wall or roof cap and any
transition needed in advance.
Use 6" round metal ductwork only.
Wall framing for adequate support
This vent hood is heavy. Adequate structure and support must be provided in all types of installations. The
hood must be secure to vertical studs in the wall, or to a horizontal support.
The vent hood should be on site before final framing and wall finishing. This will help to accurately locate
the duct work and electrical service.
Installation will be easier if the vent hood is installed before the cook-top and countertop are installed.
Installation Instructions