Dimensions and Clearances
Ductless (Recirculating) version ONLY
NOTE: -
Ducting Options and Examples
Closely follow the instructions set out in this manual.
manual, is declined.
Venting methods
B for discharge of
fumes to the outside (Ducting version).
Should it not be possible to discharge cooking fumes and
vapour to the outside, the hood can be used in the Ductless
(Recirculating) version.
F on the duct cover support bracket G. Fumes and
vapours are recycled through the top grille H by means of a
duct connected to the transition B and the transition mounted
F.
NOTE: For ductless (Recirculating) version only:
purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version):
6” Round Pipe.
12"
13" ¼
*Mín. 29" 13/64
*Máx. 49" 13/64
Mín. 29" 13/64
Máx. 43" 13/64
25" ¼
36"
6 - 13/16"
Preparation
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
-
CAUTION:
FOR 8’ CEILINGS: MOUNT THIS HOOD SO THAT THE
BOTTOM EDGE IS AT 27” (68,6 CM) MINIMUM ABOVE
THE COOKING SURFACE.
FOR 9’ CEILINGS: MOUNT THIS HOOD SO THAT THE
BOTTOM EDGE IS AT 30” (76,2 CM) MINIMUM ABOVE
THE COOKING SURFACE.
Check your ceiling height and the hood height maximum
before you select your hood.
Pipe
F-H-G
Ductless (Recirculating)
version
Ducted version
B
Pipe
B