Electrical & Installation Requirements
ELECTRICAL REQUIREMENTS
IMPORTANT:
• Observe all governing codes and ordinances.
• It is the customer’s responsibility:
o Tocontactaqualiedelectricalinstaller.
o To assure that the electrical installation is adequate and in conformance with National Electrical Code,
ANSI/NFPA70 latest edition* and all local codes and ordinances.
• Ifcodespermitandaseparategroundwireisused,itisrecommendedthataqualiedelectriciandeterminethat
the ground path is adequate.
• Do not ground to a gas pipe.
• Checkwithaqualiedelectricianifyouarenotsurethattherangehoodisproperlygrounded.
• Do not have a fuse in the neutral or ground circuit.
• Save installation instructions for electrical inspector’s use.
• The range hood must be connected with copper wire only.
• Therangehoodshouldbeconnecteddirectlytothefuseddisconnect(orcircuitbreaker)boxthroughmetalelectrical
conduit.
• WiresizesmustconformtotherequirementsoftheNationalElectricalCodeANSI/NFPA70latestedition*and
all local codes and ordinances.
• U.L.(underwrittersLaboratories)listedconduitconnectormustbeprovidedateachendofthepowersupplyconduit
(attherangehoodandatthejunctionbox).
* Copies of the standards listed may be obtained from:
National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269
Electric requirements
• Theseventhoodsmustbepowersupplied120V,60Hz,andconnectedtoanindividual,properlygroundedbranch
circuit, and protected by 15 or 20 Amps circuit breaker or fuse.
• Wiring must be two wire with ground.
• If the electrical supply does not meet above requirements, call a licensed electrician before proceeding.
• Routehousewiringasclosetotheinstallationlocationaspossible,intheceilingorbackwall.
• The hood must be connected to the house wiring in accordance with the local codes.
CAUTION: This appliance should be properly grounded.
Before installing the hood
• Forthemostefcientairowexhaust,useastraightrunorasfewelbowsaspossible.
CAUTION: Vent unit to outside of building only.
• At least two people are needed for installation.
• Onaverageonetothreehoursarenecessarytocompleteinstallation(withoutconsideringcuttobedoneonwall
and/oroncabinet,installationducts,conduitandelectricalconnectionstothemains).
• Thehoodisttedwithscrewsandwallanchorssuitableformostsurfaces,consultaqualiedinstaller,checkif
theyperfectlytwithyourcabinet/wall.
• Donotuseexducting.
• COLDWEATHERinstallationsshouldhaveanadditionalnonreturnvalve(Accessorynotprovidedwiththehood)
installedtominimizebackwardcoldairowandathermalbreaktominimizeconductionofoutsidetemperatures
as part of the duct work. The damper should be on the cold air side of the thermal break.
• Makeup air local building codes may require the use of makeup air systems when using ducted ventilation systems
greaterthanspeciedCFMofairmovement.ConsultyourHVACprofessionalforspecicrequirementsinyour
area.