Installation Instructions
Connecting the ductwork
• Installductwork,makingconnectionsinthedirectionofairowasillustrated.
• Push duct over the exhaust outlet.
• Wrapallductjointsandtheangeconnectionswithducttapeforanairtightseal.
• Make the same connection in the wall or ceiling vent exit.
Making the electrical connections
WARNING:
ELECTRICAL SHOCK HAZARD
TURN OFF POWER CIRCUIT AT THE SERVICE PANEL BEFORE WIRING THIS UNIT.
120 V, 15 OR 20 AMP CIRCUIT REQUIRED.
IF HOUSE WIRING IS NOT A 3 WIRE INSTALLATION (NEUTRAL, LINE AND GROUND), A GROUND MUST BE
PROVIDED BY THE INSTALLER. WHEN HOUSE WIRING IS ALUMINUM, BE SURE TO USE U.L. APPROVED
ANTI-OXIDANT COMPOUND AND ALUMINUM-TO-COPPER CONNECTORS.
ELECTRICAL GROUNDING INSTRUCTIONS
THISAPPLIANCEISFITTEDWITHANELECTRICALJUNCTIONBOXWITHTHREEWIRES,THEWIRECOLOR
GREEN/YELLOWSERVESTOGROUNDTHEAPPLIANCE.TOPROTECTYOUAGAINSTELECTRICSHOCK,
THEGREEN/YELLOWWIREMUSTBECONNECTEDTOTHEGROUNDINGWIREINYOURHOMEELECTRICAL
SYSTEM,ANDITMUSTUNDERNOCIRCUMSTANCESBECUTORREMOVED.FAILURETODOSOCANRESULT
INDEATHORELECTRICALSHOCK.
• Removejunctionboxcoverandknockoutonthetopleftside.