Venting Outside Through the Roof
Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent. Go to Step 3.
A
B*
C
D
A. Cutout
B.6¼”(15.9cm)*
C. 7¾”(19.7cm)centerlinetocabinetfront
D. Centerline
*NOTE:For12”(30.5cm)highcabinetsa6¼”deepx8”wide
(14.6cmx20.3cm)rectangularopeninginthecabinettopis
required for damper transition clearance.
Venting Outside Through the Wall
Installthe6”(15.2cm)venttransitiontothetopoftherange
hood liner using two 3.5 x 9.5 mm screws. Assemble the vent
ductthatyouwilluseoverthe6”(15.2cm)venttransition.
Measure from the bottom of the range hood liner to the
horizontalcenterlineoftheventopening(A).
A
B
C
A. Measurement A
B. Horizontal centerline of vent opening
C. Range hood liner
Remove the vent duct from the range hood liner.
Transfer measurement A to the cabinet back wall. Measure
from the underside of the cabinet. Mark the cutout as shown.
Use a saber saw or keyhole saw to cut a round opening
through the back of the cabinet and the exterior wall for the
vent. Go to Step 3.
A
B
C
A. Measurement A
B. Centerline
C.6¼”(15.9cm)round
cutout
Non-Vented (recirculating) Installation Through the
Soft/Cabinet
E
A
B
G
D
F
H
I
A
B
G
F
C
D
E
A. Ceiling
B. Vent cover
C. Soffit
D.6”(15.2cm)vent
E. Range hood
F. Cabinet
G.Wall
H.12”(30.5cm)min.cabinetheight
I.17”(43.2cm)min.ventcoverheight
Measureandmarkthecenterlineofthecabinettothesoft
above.
Measure from the bottom of the cabinet to the centerline of
thewheretheventwillcomethroughthesoft.Markthe
location and use a saber saw or keyhole saw to cut a 5¾”
(14.6cm)holefortheventcover.
A
B
A. Vent cover
B. Centerline
*NOTE:For12”(30.5cm)highcabinetsa6¼”deepx8”wide
(14.6cmx20.3cm)rectangularopeninginthecabinettopis
required for damper transition clearance.
Measure and mark the centerline location for the cutout in the
cabinet top. Use a saber saw or keyhole saw to cut an
opening for the vent.
A
B
C
D
A. Cutout
B. See chart below
C. 7¾”(19.7cm)center-
line to cabinet front
D. Centerline
Cabinet Height Hole Shape and Size
12”(30.5cm) A6¼”deepx8”wide(15.9cmx20.3cm)
rectangular opening in the cabinet top is
required for damper transition clearance.