6
Venting Methods
This range hood is factory set for venting through the roof or
through the wall. You can apply the recirculating venting method
by purchasing the Recirculation Kit.
The vent system needed for installation is not included.
A6”(15.2cm)roundventsystemisrecommended.
Roof Venting
A.6”(15.2cm)vent
through the roof
B. Roof cap
Wall Venting
A.6”(15.2cm)vent
through the wall
B. Wall cap
Recirculating
A.6”(15.2cm)vent
through the cabinet
B. Round recirculating grid
Calculating Vent System Length
Therecommendedventsystemis6”(15.2cm)roundventwitha
maximumlengthof35ft(10.7m).Forthebestperformance,use
no more than three 90° elbows.
To calculate the length of the system, add the equivalent feet
(meters)foreachoftheventpiecesusedinthesystem.
Vent Piece 6” (15.2 cm)
45° elbow 2.5 ft
(0.8m)
90° elbow 5.0 ft
(1.5m)
Example Vent System
90° elbow
Wall cap
2ft(0.6m)
6ft(1.8m)
Maximum Recommended Length = 35 ft (10.7 m)
1-90°elbow =5.0ft(1.5m)
1-wallcap =0.0ft(0.0m)
9ft(2.8m)straight =9.0ft(2.8m)
Length of 6” (15.2 cm) system = 14.0 ft (4.3m)
WARNING
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, re, or electrical shock.
IMPORTANT: The range hood must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
(latestedition)orCanadianElectricalCode,CSAC22.1
No.0-M91(latestedition).
If codes permit and a separate ground wire is used, it is
recommendedthataqualiedelectricalinstallerdeterminethat
the ground path is adequate.
Electrical Requirements
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy,MA02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland,Ohio44131-5575
■ A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required.A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range hood be provided.
■ This range hood is equipped with a power supply cord having
a 3 prong grounding plug.
■ To minimize possible shock hazard, the cord must be
plugged into a mating, 3 prong, grounding-type outlet,
grounded in accordance with local codes and ordinances. If a
mating outlet is not available, it is the personal responsibility
and obligation of the customer to have the properly grounded
outletinstalledbyaqualiedelectrician.